FreeCAD Logo FreeCAD 1.0
  • English Afrikaans Arabic Belarusian Catalan Czech German Greek Spanish Spanish Basque Finnish Filipino French Galician Croatian Hungarian Indonesian Italian Japanese Kabyle Korean Lithuanian Dutch Norwegian Bokmal Polish Portuguese Portuguese Romanian Russian Slovak Slovenian Serbian Swedish Turkish Ukrainian Valencian Vietnamese Chinese Chinese
  • Features
  • Download
  • Blog
  • Documentation
    Documentation index Getting started Users documentation The FreeCAD manual Workbenches documentation Python coding documentation C++ coding documentation Tutorials Frequently asked questions Privacy policy About FreeCAD
  • Contribute
    How to help Sponsor Report a bug Make a pull request Jobs and funding Contribution guidelines Developers handbook Translations
  • Community
    Code of conduct Forum The FPA GitHub GitLab Codeberg Mastodon Matrix IRC IRC via Webchat Gitter Discord Reddit Twitter Facebook LinkedIn Calendar
  • ♥ Donate

Donate

$
SEPA Information
Please set up your SEPA bank transfer to:
Beneficiary: The FreeCAD project association
IBAN: BE04 0019 2896 4531
BIC/SWIFT: GEBABEBBXXX
Bank agency: BNP Paribas Fortis
Address: Rue de la Station 64, 1360 Perwez, Belgium

While Stripe doesn't support monthly donations, you can still become a sponsor! Simply make a one-time donation equivalent to 12 months of support, and you'll gain access to the corresponding sponsoring tier. It's an easy and flexible way to contribute.

If you are not sure or not able to commit to a regular donation, but still want to help the project, you can do a one-time donation, of any amount.

Choose freely the amount you wish to donate one time only.

You can support FreeCAD by sponsoring it as an individual or organization through various platforms. Sponsorship provides a steady income for developers, allowing the FPA to plan ahead and enabling greater investment in FreeCAD. To encourage sponsorship, we offer different tiers, and unless you choose to remain anonymous, your name or company logo will be featured on our website accordingly.

from 1 USD / 1 EUR per month. You will not have your name displayed here, but you will have helped the project a lot anyway. Together, normal sponsors maintain the project on its feet as much as the bigger sponsors.

from 25 USD / 25 EUR per month. Your name or company name is displayed on this page.

from 100 USD / 100 EUR per month. Your name or company name is displayed on this page, with a link to your website, and a one-line description text.

from 200 USD / 200 EUR per month. Your name or company name and logo displayed on this page, with a link to your website and a custom description text. Companies that have helped FreeCAD early on also appear under Gold sponsors.

Instead of donating each month, you might find it more comfortable to make a one-time donation that, when divided by twelve, would give you right to enter a sponsoring tier. Don't hesitate to do so!

Choose freely the amount you wish to donate each month.

Please inform your forum name or twitter handle as a notein your transfer, or reach to us, so we can give you proper credits!

Static Current Equation
Flux Equation
FEM

FEM EquationFlow

Menu location
Solve → Flow Equation
Workbenches
FEM
Default shortcut
None
Introduced in version
0.17
See also
None

Description

This equation calculates viscous fluid flows using the Navier-Stokes equations.

For information about the math of the equation, see the Elmer models manual, section Navier-Stokes Equations.

Usage

  1. Add an Elmer solver.
  2. Select it in the Tree View.
  3. There are several ways to invoke the command:
    • Press the Flow Equation button.
    • Select the Solve → Flow Equation option from the menu.
  4. Change the equation's solver settings or the general solver settings if necessary.

Solver Settings

For the general solver settings, see the Elmer solver settings.

The flow equation provides these special settings:

  • DataDiv Discretization: To be set to true for incompressible flow for more stable discretization when the Reynolds number increases.
  • DataFlow Model: The flow model that should be used. The default Full includes convection and time derivative terms in the model. No convection switches off the convection terms and the Stokes model switches off the convection terms and the (explicit) time derivative terms.
  • DataGradp Discretization: If set to true pressure Dirichlet boundary conditions can be used. Also the mass flux is available as a natural boundary condition.
  • DataVariable: Optional only for calculations in 2D: You can change the default of 3 to 2.
    Note: In this case none of the flow velocity boundary conditions can have a specified z-component.

Equation:

  • DataConvection: The type of convection to be used in the Heat equation.
    Note: For thermal flows it must be set to Computed (the default).
  • DataMagnetic Induction: If set to true the magnetic induction equation will be solved along with the Navier-Stokes equations.

Notes for Convergence

If the solver results do not converge, you can try these things (in the given order):

  1. Reduce the DataRelaxation Factor, see the nonlinear system settings.
  2. Increase the value for DataNonlinear Newton After Iterations, see the nonlinear system settings.
  3. Reduce the number of CPU cores used, see the FEM preferences.
  4. Increase the mesh density (make it more fine).

Analysis Feature Information

The flow equation takes the following analysis features into account if they are set:

  • Flow velocity boundary condition
  • Initial flow velocity condition
  • Pressure load
  • Initial pressure condition (introduced in 0.21)

Notes

  • Except for calculations in 2D, for all above boundary conditions it is important that they act on a face or body. Boundary conditions for 3D set to lines or vertices are not recognized by the Elmer solver.
  • Since Pressure load can only be set to faces, pressure loads cannot be used for calculations in 2D.
  • If there is no Pressure load set, Initial pressure condition will only be taken into account if DataGradp Discretization is set to true.

Results

The results are the velocity in m/s and the pressure in Pa. If there is no Initial pressure condition and Pressure load given, the resulting pressure will be relative not absolute. Since pressure must act on a face, absolute pressure results cannot be obtained in 2D simulations.


Static Current Equation
Flux Equation
FEM

This page is retrieved from https://wiki.freecad.org/FEM_EquationFlow

Get in touch!
Forum GitHub Mastodon Matrix IRC Gitter.im Discord Reddit Twitter Facebook LinkedIn

© The FreeCAD Team. Homepage image credits (top to bottom): ppemawm, r-frank, epileftric, regis, rider_mortagnais, bejant.

This project is supported by: , KiCad Services Corp. and other sponsors

GitHubImprove this page on GitHub