Расположение в меню |
---|
Model → Thermal Constraints → Constraint initial temperature |
Верстаки |
FEM |
Быстрые клавиши |
Нет |
Представлено в версии |
- |
См. также |
FEM tutorial |
Описание
Defines an initial temperature for a thermo-mechanical analysis.
Применение
- There are several ways to invoke the command:
- Press the
Initial temperature button.
- Select the Model → Thermal boundary conditions and loads →
Initial temperature option from the menu.
- Press the
- Enter an initial temperature value for the analysis.
Ограничения
This tool applies the initial temperature to all nodes in the FEA model - it's not possible to select individual regions.
Примечания
- This tool uses the *INITIAL CONDITIONS card in CalculiX.
- Initial temperature has to be defined for all thermomechanical analyses performed with CalculiX, even the steady-state ones.