GuiCommand:Container| {{GuiCommand Name: FEM ConstraintBodyHeatSource MenuLocation: Model , Thermal boundary conditions and loads , Body heat source Workbenches: FEM_Workbench Version: 0.19 SeeAlso: FEM_tutorial }} {{GuiCommandFemInfo Solvers: CalculiX, Elmer }}
FEM ConstraintBodyHeatSource
Description
Defines an internally generated body heat given in W/kg.
(v1.0)
: Can also define the heat source in W.
Usage
-
Press the
'''Body heat source''' button or select Model → Thermal boundary conditions and loads →
Body heat source from the menu.
-
(v0.21) : Press the Add button. For a 3D analysis, select a \'solid\' (body) from your model, for a 2D analysis select a face.
-
Set the value:
{{VersionMinus|0.20}} : Since the tool has no task dialog, use the [property editor](wiki-test2.php?gitpage=Property_editor) and set the property **Heat Source**.
-
(v0.21)
: Enter the body heat in W/kg.
-
(v1.0)
: Select the mode:
- Dissipation Rate - enter the dissipation rate in W/kg .
- Total Power - enter the total power in W.
-
Limitations
-
{{VersionMinus|0.20}}: The body heat source is applied to the whole model, meaning all bodies of the setup. It is not possible to select an individual body.
-
{{VersionMinus|0.21}}: This feature only works with the Elmer solver.
Notes
-
For more information see this forum thread and following posts. This thread may also be useful.
-
Elmer examples can also be found in Elmer GUI Tutorials.
-
(v1.0) : This feature uses the *DFLUX card in CalculiX.
-
(v1.0) : Since CalculiX expects body heat flux input in W/mm\^3 while for Elmer it\'s W/kg, the conversion of the specified value (in W or W/kg) is done internally for each solver, using the volume of the selected solid and the density of the material assigned to it, if needed.